Optimizing Ozone Disinfection for Water Processes With ...

2022-05-14 06:36:40 By : Mr. John Zhang

Fluid Components International LLC. (FCI)

Source: Fluid Components International LLC. (FCI)

Chlorine-Free Disinfection With Virtually No Flow Meter Maintenance

San Marcos, CA -- Water engineers and plant managers will find the rugged ST80 Thermal Flow Meter Series from Fluid Components International (FCI) provides precision air/gas measurement that helps them optimize their Ozone (O3) disinfection process to avoid the use of harsh Chlorine (Cl2) chemicals while at the same time reducing their busy technician’s meter maintenance requirements to almost zero.

FCI’s ST80 Air/Gas Flow Meter Series, which is available in either insertion or inline configurations, is well suited for air or gas line flow measurements in various water treatment plant applications. The insertion style meter, for example, operates over a wide flow range of  0.25 to 1000 SFPS (0,07 to 305 NMPS). The ST80 Series is factory calibrated and can provide a flow turndown range of 2:1 to 100:1; surpassing the capabilities of other flow meter technologies in variable demand flow processes.

Ozone is an unstable molecule that can easily be converted to Oxygen (O2).  As an oxidizer, it becomes a strong disinfectant that can be applied for water treatment that kills dangerous organisms within raw water supplies to make the water safe for human consumption.  There are several different types of Ozone water treatment systems.  Each type of treatment system has its particular benefits and short-comings.

All Ozone systems, however, provide excellent disinfection and eliminate some of the chemical by-product problems caused by water chlorination. They also produce no odors or after-taste, which makes the finished water more palatable.  In addition, the efficiency and operational cost of O3 disinfection systems have one more thing in common:  They are highly dependent on accurate, dependable air/gas flow measurement in harsh conditions for efficient operation.

With its built-in temperature compensation, the ST80 Flow Meter offers highly repeatable performance under various process environments. It features accuracy up to ±1% of reading with ±0.5% repeatability over variable process temperatures and pressures in line sizes from 2 inches (6 mm) and up. 

O3 Disinfection With ST80 Flow Meter Series

The ST80 Flow Meter’s thermal dispersion flow sensor design is elegant in that it does not utilize any moving parts by employing solid-state platinum RTD sensors that are precision matched and embedded in equal mass thermowells. The sensor’s design requires virtually no cleaning and is less prone to fouling than other flow measurement technologies when there is a concern about particulate laden gas streams. 

The durable and highly reliable ST80 Flow Meter is optionally available with remote mounting capabilities where space is at a premium or the measurement point is not easily accessed.  The remote mount transmitter, which has an option for local indication of flow, temperature and totalized flow, can be mounted up to 1000 feet (300 meters) away from the flow sensor in the process piping.

The ST80 Flow Meter Series features scalable dual 4-20mA outputs are standard. They are user assignable to flow rate or temperature. Outputs are user programmable to full flow range or subsets of full flow range.  They are also isolated and have fault indication per NAMUR NE43 guidelines, and they user selectable for high (>21.0 mA) or low (  Standard digital outputs available include: HART (v7 compliant), Modbus RS-485 and USB Serial I/O.  Optional: digital outputs that can added are Foundation Fieldbus H1, PROFIBUS-PA, or PROFIBUS-DP

Offering mass flow measurement for higher performance at an economical price with proven thermal dispersion technology, the ST80 Series Flow Meters eliminate the need for additional pressure and temperature sensors, flow computers, or other devices that are required with orifice plates, Venturis, Vortex shedding, and other volumetric meters.  The ST80 Flow Meter also requires virtually no maintenance for both a low installed and low life-cycle cost.

The highly reliable ST80 Series Flow Meter also carries numerous agency approvals and certifications, including: ATEX, CE, CPA, CRN, FMc, FM, EAC/TR CU, EQM/ECAS, IECEx, NEPSI, SIL (IEC 61508), UKCA (UKEX).

Fluid Components International is a global company committed to meeting the needs of its customers through innovative solutions for the most challenging requirements for sensing, and measuring flow, pressure and temperature of gases.

FPI Launches CO2 Analyzer to Attain the Goal of Carbon Peaking

In 2021, to achieve the goal of carbon peaking by 2030 and carbon neutrality by 2060, the Ministry of Ecology and Environment has issued the Guidance on Coordinating and Strengthening the Work Related to Climate Change Response and Ecological Environmental Protection and the Carbon Monitoring and Assessment Pilot Work Program. Proposing to strengthen greenhouse gas detection and implement reduction pollution and carbon, thus further optimizing the energy mix and driving industries to improve efficiency and reduce...

Toshiba wins contract for ozone treatment system at Chandrawal Water Treatment Plant in Delhi

Toshiba Infrastructure Systems & Solutions Corporation have concluded a contract with Larsen & Toubro Limited (hereafter L&T) for three ozone generators at the Chandrawal Water Treatment Plant in Delhi, India, being executed by Delhi Jal Board. This is one of the largest-scale ozonation systems for a water treatment plant in India. The project is funded by Japan International Cooperation Agency (hereafter JICA) under the Delhi Water Supply Improvement Project. JICA assisted 477MLD Water Treatment...

Ozone vs. Chlorine for water disinfection

Ozone and chlorine have very similar disinfectant properties. However, their uses today differ due to the environmental consciousness of our society. For several reasons, Ozone systems are still uncommon in much of the world. On the other hand, chlorine continues to be used disinfectant in every region of the world. As ozone is more reliable, easier to use, and safer to operate, it has gained popularity in many disinfection applications. High oxidation potential, very effective disinfection ability, quicker...

FPI Pioneered Use of Chemiluminescence Method in Ozone Pollution Monitoring

Ambient air—Automatic determination of ozone—Chemiluminescence method (HJ 1225-2021), a new national standard issued by the Ministry of Ecology and Environmental of the PRC, was officially implemented on March 1st, 2022. Compared to the previous national standard——the UV absorption method, the chemiluminescence method, is characterized by strong selectivity and high measurement accuracy. The UV absorption method measures the concentration of ambient ozone based on the absorption of the...

Praxis/Urban Air Quality Monitors deployed in Oxford

16 Praxis/Urban air quality monitors have been deployed around the city of Oxford as part of the OxAria research project. South Coast Science is one of the commercial partners for the project, supplying air quality monitoring devices. OxAria is a collaboration between academic, public and commercial partners that aims to understand the air and noise quality impacts of COVID-19 across Oxford city. It is led by the Universities of Birmingham and Oxford and funded by the Natural Environmental Research Council.

No comments were found for Optimizing Ozone Disinfection for Water Processes With Thermal Flow Meter Reduces Maintenance Costs. Be the first to comment!

Environmental XPRT is a global environmental industry marketplace and information resource. Online product catalogs, news, articles, events, publications & more.

Environmental XPRT is part of XPRT Media All Rights Reserved. Terms Privacy

Our sites: Agriculture XPRT Energy XPRT Medical XPRT XPRT